kathy@zozen.com
Product thermal capacity: 0.35-14 MW
Working pressure: 0.7-1.25 Mpa
Available industries: Heat supplying, hospital, hotel
Product thermal capacity: 10-50 t/h
Working pressure: 1.25-2.5 Mpa
Outlet temperature: 194-225 °C
Product thermal capacity: 20-75 t/h
Working pressure: 1.25-5.4 MPA
Outlet temperature: 184-485 ℃
Product thermal capacity: 1 – 20t/h
Working pressure: 0.7-2.5 MPA
Outlet temperature: 170-225 ℃
A fire-tube boiler is a type of boiler in which hot gases pass from a fire through one or more tubes running through a sealed container of water. The heat of the gases is transferred through the walls of the tubes by thermal conduction, heating the water and ultimately creating steam.. The fire-tube boiler developed as the third of the four major historical types of boilers: low-pressure tank
View MoreCertain basic design flaws can contribute to tube failures. Problems which occur as a result of a design flaw may be intensified by the boiler water chemistry. The boiler water often contains elements that become corrosive when concentrated far beyond normal values as a result of design problems.
View MoreBoilersupplies supplies everything you need in your boiler room. Shop online for boiler pumps,heat exchangers, replacement parts, valves, gage glass & more!
View MoreThe trays are placed in each drum of a water tube boiler, or on the top flues of a fire-tube unit. All manholes, handholes, vents, and connections are blanked and tightly closed. The boiler should be opened every month for inspection of the desiccant. Following chemical cleaning with a water solution, the fireside should be dried by warm
View MoreThe MPH boiler's three-pass design is a smart choice for combatting rising fuel costs. The boiler achieves 83%+ fuel efficiencies by circulating the flue gases through the boiler 3 times. The longer flue gases stay in your boiler, the higher the efficiency achieved. The three-pass design is the most effective and fuel efficient boiler design.
View MoreFireside Gasket Kits; Fiberglass Boiler Rope, Flat Tape and Tadpole Gaskets; Low Water Cut-Off & Sight Glass Gaskets; Tube Plug Gaskets; Port Sealed Gaskets for Section Assembly; Ceramic Fire Blankets; Woven Fiberglass Gaskets
View MoreFor an upcoming annual inspection, we recommend cleaning the burner assembly including flame sensors and igniters along with the boiler furnace, tubes and tube sheets. Additionally, you can clean the handhole and manhole plates by removing then flushing boiler with water to remove Zozene scale and sediment. Routine Boiler Inspection
View MoreShell and tube exchanger Water tube boiler Multiple drum system low pressure (LP) medium pressure (MP) high pressure (HP) Multi Pressure Boiler System with Integral Deaerator. Fireside Waterside Fireside Waterside Metal Metal Scale Without deposits With deposits 600°F 500°F 500°F 800°F and …
View MorePractical Boiler Operation Engineering Power plants 26. Cooling Water Treatment and Cooling Towers 27. Water Treatment and Demineralization 28. Reverse Osmosis 29. Scaling of Fireside of Heating Surfaces 30. Corrosion of Waterside Heating Surfaces 31. Corrosion of Fireside Heating Surfaces 32. Evaporators 33. Superheaters 34. Economizers and
View MoreBoiler Water Treatment. Cleanup. Closed System Treatment. Cooling Tower Treatment. Cooling Water Treatment. Tube Mill Coolant. Vanishing Fluid. Iron Phosphate. Non-Phosphate. Paint Stripper. Zinc Phosphate. Fireside. Internal Boiler - Alkalinity Builder. Internal Boiler - All-in-One Treatment
View MoreSymptoms: Aggressive localized boiler tube corrosion and loss of tube wall.Pits can act as stress-concentration sites which can be initiation points for stress-related corrosion mechanisms. Causes: Oxygen pitting occurs with the presence of excessive oxygen in boiler water.It can occur during operation as a result of in-leakage of air at pumps, or failure in operation of preboiler water
View MoreIn a scotch boiler, the furnace is a large diameter tube, within the boiler, surrounded by water. Some older, large scotch boilers had two or three furnaces but modern boilers typically have only one. Scotch boilers may be two-pass, three-pass, or four-pass depending upon the arrangement of baffles and tubes.
View MoreBoiler inspections are crucial for any industry that uses industrial boilers. Water-tube boilers are more efficient than fire-tube boilers, but also more complex and All fireside conditions are inspected inside the boiler, includiREAD MORE Boiler fire side - problems, inspection, Maintenance and - YouTube
View MoreFeb 01, 2019 · Prior to that time, formation of hard scale and severe corrosion led to boiler tube failures and explosions. Soda ash/washing soda (Na 2 CO 3) was the first chemical used to treat boiler water
View MoreFill the boiler to its normal operating level with water hotter than 180°F. This temperature helps drive off dissolved gases. If hot water is not available, heat the water using the boiler’s burner after the water level reaches the lowest permissible level as marked on the boiler. Vent the air and gases as needed.
View MoreTube failure is one of the major problems occurring in the boiler. 30% of tube failures occur in the economizer. Economizer tubes face fireside (external) and waterside (internal) corrosion. The fireside corrosion is a function of flue gas components, tube metal temperature, and the method of firing.
View MoreFireside Fusible Plug Model 28-403 conforms to ASME standards, with maximum pressure of 250 lbs. Fusible plugs are installed between the fireside of either the plate, flue or tube of the boiler and below the water level; 28-400 models are manufactured to conform to ASME standards and meet U.S. Coast Guard requirements
View MoreMost water-bearing tubes used in boiler construction are fabricated from low-carbon steel. However, steam-bearing (superheater and reheater) tubes are commonly fabricated from low-alloy steel containing differing levels of chromium and molybdenum. Chromium and molybdenum increase the oxidation and creep resistance of the steel.
View MoreFireside-SG is a single component ceramic coating specifically engineered to provide increased thermal conductivity in gas fired boilers and fired heaters. This coating can be applied on both carbon and stainless steel boiler and furnace tubing.
View MoreThe breakthrough in water tube boiler design that pro-duced the RV Series provides operating efficiency so reliable, we guarantee it to be 84% for hot water boilers and 82% - 15 psi / 80% - 150 psi or better for steam boilers. The Bryan Flexible Tube Bryan’s exclusive “Flexible Tube” design eliminates the possibility of damage
View MoreMar 19, 2016 · The main difference between fire tube and water tube is that in fire tube boiler the flue gases flow in the tubes and water flows from the shell and in water tube boiler, water flows from the tubes and the flue gases from the shell or passes over the tubes. This is the key difference between these boilers.
View MoreOur Unilux boilers are the first and only 5-pass, bent-tube boilers that operate at 85% efficiency, standard. The tangent tube design allows for unsurpassed convective internal pumping and maximum heat transfer. Standard design pressure is 160 PSI / ASME Section IV, with higher pressures available. Flexible burner selection
View MoreCauses and corrective measures are reviewed for several common types of fireside corrosion in kraft recovery boilers. Corrosion differs significantly with location in the boiler due tio the great
View MoreBoilers designed for oil firing incorporate design parameters that allow for relatively trouble-free operation from a fireside standpoint. Combustion gas velocity, tube spacing, furnace gas exit temperature, and economizer configuration are adjusted to account for oil ash characteristics.
View More